Customization: | Available |
---|---|
Type: | Self-Starting Diesel Generator |
Installation Method: | Fixed |
Still deciding? Get samples of US$ 37000/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
PRODUCT DESCRIPTION |
Frequency: 50HZ;Rotating speed: 1500Rpm | |||||
Model | Power(KW) | Capacity(KVA) | Rated current(A) | Engine Model | Original Stanford |
BS-D60 | 48 | 60 | 86.6 | BF4M2012 | UCI224E |
BS-D75 | 60 | 75 | 1082 | BF4M2012C | UCI224F |
BS-D100 | 80 | 100 | 144.3 | BF4M1013EC | UCI274C |
BS-D125 | 100 | 125 | 180.4 | BF4M1013FC | UCI274D |
BS-D160 | 128 | 160 | 230.9 | BF6M1013EC | UCI274F |
BS-D188 | 150 | 155 | 270.6 | BF6M1013FCG2 | UCI274G |
BS-D200 | 160 | 200 | 288.6 | BF6M1013FCG3 | UCI274H |
BS-D230 | 184 | 230 | 331.9 | BF6M1015-LA GA | UCD274J |
BS-D250 | 200 | 250 | 360.8 | BF6M1015C-LA G1A | UCD274K |
BS-D300 | 240 | 300 | 433 | BF6M1015C-LA G2A | HCI444D |
BS-D325 | 260 | 325 | 469 | BF6M1015C-LA G3A | HCI444ES |
BS-D350 | 280 | 350 | 505 | BF6M1015C-LA G4 | HCI444E |
BS-D375 | 300 | 375 | 541.2 | BF6M1015CP-LA G | HCI444FS |
BS-D438 | 350 | 438 | 631.4 | BF8M1015C-LA G1A | HCI544C |
BS-D450 | 360 | 450 | 649.5 | BF8M1015C-LA G2 | HCI544C |
BS-D463 | 370 | 463 | 667.5 | BF8M1015CP-LA G1A | HCI544C |
BS-D500 | 400 | 500 | 721.7 | BF8M1015CP-LA G2 | HCI544C |
BS-D550 | 440 | 550 | 793.8 | BF8M1015CP-LA G4 | HCI544D |
BS-D575 | 460 | 575 | 829.9 | BF8M1015CP-LA G5 | HCI544E |
Frequency: 60HZ;Rotating speed: 1800Rpm | |||||
Model | Power(KW) | Capacity(KVA) | Rated current(A) | Engine Model | Stanford Type |
BS-D70 | 56 | 70 | 101 | BF4M2012 | UCI224E |
BS-D88 | 70 | 87.5 | 126.3 | BF4M2012C | UCI224F |
BS-D114 | 91 | 114 | 164 | BF4M1013EC | UCI274C |
BS-D130 | 104 | 130 | 187.6 | BF4M1013FC | UCI274D |
BS-D168 | 134 | 168 | 241.7 | BF6M1013EC | UCI274E |
BS-D190 | 152 | 190 | 274.2 | BF6M1013FCG2 | UCI274F |
BS-D213 | 170 | 213 | 306.7 | BF6M1013FCG3 | UCI274G |
BS-D250 | 200 | 250 | 360.8 | BF6M1015-LA GA | UCI274J |
BS-D275 | 220 | 275 | 396.9 | BF6M1015C-LA G1A | UCI274J |
BS-D313 | 250 | 313 | 451 | BF6M1015C-LA G2A | HCI444D |
BS-D350 | 280 | 350 | 505 | BF6M1015C-LA G3A | HCI444D |
BS-D456 | 365 | 456 | 658.5 | BF6M1015C-LA G4 | HCI444F |
BS-D488 | 390 | 488 | 703.6 | BF6M1015CP-LA G | HCI544C |
Genset Model | BS-D513 | ||
Prime Power (kw/kva) | 410 / 513 | Standby Power(kw/kva) | 451 / 564 |
Voltage (v) | 400 | Rated Speed (rpm) | 1500 |
Frequency (Hz) | 50 | Rated Current (A) | 740 |
Connection: | 3 phase | Power Factor: | 0.8 |
Engine Model: | BF8M1015CP-LA G3 | Alternator Model: | HCI544D |
Net Weight (kgs)-Silent | 5500 | Dimensions (mm)-Silent | 5000x1800x2450 |
Engine Parameter: | |
Manufacturer/Model: Engine type: Control System: Displacement: Bore x Stroke Compression Ratio: Power: Effective pressure: MAX. exhaust gas temperature: Inlet air (25 /1000mbar): Fuel Consumption: Max. noise value at 1m : Battery voltage(V): Starter rated power (KW): Generator voltage(V): Max. exhaust back pressure (mbar): Max. allowable air inlet resistance (mbar): Lowest ambient temperature of cold starting without assistant: Lowest ambient temperature of cold starting with flame preheat plug: |
DEUTZ BF8M1015CP-LA G3 4-Cycle,8-Cylinder,V-form,Turbocharged mechanical /electronic 15.874 L 132 x 145 mm 16.5 : 1 509 KW 25.6 bar 550ºC 2079 m3/h 196g/kw·h ≤99 dBA 24 9 28.5 50 50 -17ºC -32ºC |
Fuel System | |
Cylinder ignition sequence: Idle speed (rpm): Low-pressure pump oil load capacity (L/h): Fuel filter element type: No. of the fuel filter element |
1-8-4-5-7-3-6-2 650 190 Disposable filter 2 |
Lube System | |
Oil Consumption (as % of fuel consumption): oil temperature 90ºC Min. oil pressure at 1500rpm: Min. oil pressure at 600rpm: Oil temperature of normal operation: Initial oil filling: Oil filter element type: No. of oil filter element: |
<0.3% of fuel consumption ≥3 bar ≥1 bar <130 ºC 48 Disposable filter 1 |
Cooling system | |
Engine coolant capacity( L): Water-pump flow (L/min): Water-pump pressure (bar): Allowable pressure loss of cooling system (include pipeline) (bar): Heat carry off by coolant (kW): In&Outlet coolant size (mm): Temperature of switch on two thermostats respectively (ºC): Temperature of switch on two thermostats totally (ºC): Max. allowable operating temperature (ºC): Temperature difference between inlet and outlet coolant (ºC): Fan : Fan connection : Fan diameter (mm): Air volume of fan(m3/s): Fan power consumption (kW): Fan transmission ratio |
21 347 1.25 ≤0.35 330 70 79/87 94/102 103 ≤8 Exhaust type Gear drive + coupler 980 6.2 ≤14.1 0.96 |
Alternator Parameter: Basic Information | |
The alternators meet the standards of: GB755, BS5000, VDE00530, NEMAMG1-22,IED34-1,CSA22.2 and AS1350 |
|
Technical Data: | |
Manufacturer: Phases: Bearing numbers: Power Factor: Protection Class: Altitude Condition: Excitation: Insulation class/Temp. rise class: Tel. Influence Factor TIF: Tel. Harmonic Factor THF: Steady State Voltage Regulation: Alternator Capacity: Efficiency: |
STANFORD HCI544D 3 1 0.8 IP23 ≤1000M Brushless, self-excitation H / H <50 <2% ≤±1% 440KW 94.3% |